Notifications
You must be signed in to change notification settings - Fork 1.1k
Open
Description
I recently installed DHT22, and to my surprise, after a few days of frost, it showed a temperature of -3274.5.
The calculations performed by dht.py are consistent with the documentation, but they are incorrect.
Example and proposal for new calculation:
class DHTBase:
def xbuf(self, buf):
self.buf = buf
class DHT22(DHTBase):
def humidity(self):
return (self.buf[0] << 8 | self.buf[1]) * 0.1
def temperature(self):
t = (self.buf[2] & 0x7f) << 8 | self.buf[3]
if self.buf[2] & 0x80:
t = - t ^ 0x7fff
return t*0.1
def main():
# hum = 69, temp=-3274.5 = -2.2
cls = DHT22()
cls.xbuf([2, 183, 255, 233, 162])
temp = cls.temperature()
hum = cls.humidity()
print(f'temp={temp:.1f} hum={hum:.1f}')
main()
Metadata
Metadata
Assignees
Labels
No labels